In brief
HMG, or menotropin, is a preparation of two pituitary gonadotropins at once: follicle-stimulating hormone (FSH) and luteinizing hormone (LH), in this vial 75 IU of each. It is a mixture of two separate molecules, not a single hormone: each activity is defined by its own bioassay and lives separately in every calculation.
This reference brings together solution preparation, IU/mL arithmetic for both components, and storage conditions for the dry form and the solution. The main principle: record the concentration as a pair of numbers – IU/mL of FSH and IU/mL of LH – and never collapse them into a single total.
Which preparation the name HMG describes
Classic menotropin is extracted from the urine of postmenopausal women: after menopause the pituitary produces gonadotropins in large quantities, and modern purification brings them to pharmaceutical purity. Both components are glycoproteins with a shared alpha subunit (92 amino acid residues) and different beta subunits: beta-FSH has 111 residues, beta-LH has 121 residues. It is the beta subunits that determine which receptor each component activates.
How HMG differs from HCG: HCG is a single hormone, an agonist of the LH/CG receptor, and it carries no FSH activity. HMG, by contrast, carries both activities at once. The materials may appear in one work programme, but they are not interchangeable, and their IU are not compared directly. A detailed portrait is in the HMG monograph.
Check the available pack sizes and the measured activities in the product page and the COA of the corresponding LOT. A batch specification may state separately how the LH activity was determined; that is part of the batch identity, not fine print.
What to know before dissolving the lyophilisate
Record the material name, the LOT, the nominal amount per vial (75 IU FSH + 75 IU LH), the supplied form and the certificate of analysis (COA) data for that exact batch. For HMG the COA must show both activities separately: FSH IU and LH IU are determined by different bioassays, and a combined '150 IU' is not a characteristic of this material. The label alone is not enough to establish the actual amount of active substance for an exact calculation.
Choosing a vehicle requires data for this exact form of the material: the solvent, an acceptable concentration, pH and compatibility with the working medium. A recipe for another protein or peptide does not prove suitability for this material. The general Bachem guide explains that solubility depends on the structure of the molecule; it does not set a universal protocol for all peptides and proteins.
Before opening, let a cold dry vial warm to room temperature while still closed, to reduce condensation reaching the material. Do not use arbitrary heating, a pH change or an organic solvent to 'rescue' a failed trial: such an intervention creates new conditions that must be documented and verified, not hidden in the preparation record.
How to check the stock solution and the working dilution
First prepare a small trial according to the specification. Record the vehicle composition, the final volume, the mixing method, the dissolution time and the initial appearance. The absence of visible precipitate is a useful observation, but it is not a measurement of how much substance has dissolved.
Then reproduce the working dilution in the actual experimental medium. Separately check the state of the sample at the end of the planned analysis time. This helps distinguish a problem with the stock solution from an incompatibility that appears only after dilution.
If the work involves serial dilutions or several transfers, include that sequence in the reproducibility check. Compare the result of a direct dilution with the result of the full transfer chain at the same final concentration. Use a compatible analytical method to assess possible losses; do not draw conclusions from transparency or the look of the tube alone.
Two activities separately: an example for the 75 + 75 IU HMG vial specifically
Each activity is calculated from the final volume separately: c = component activity / V. An example of teaching arithmetic, not a recommended concentration: a vial of 75 IU FSH + 75 IU LH brought to a final volume of 1.0 mL gives 75 IU/mL of FSH and 75 IU/mL of LH. The same vial in a final volume of 0.5 mL gives 150 IU/mL of each component.
No conversion to milligrams exists for HMG, not even through a single specific activity: the mixture holds two proteins with different specific activities, and the pharmacopoeial characteristic of the material is precisely the pair of activities in IU. Coefficients of other hormones, in particular the somatropin '1 mg ≈ 3 IU', are not applied to menotropin.
For further dilution use c₁V₁ = c₂V₂ separately for each component; in a simple dilution with a vehicle both concentrations change by the same factor, and the FSH:LH ratio of 1:1 is preserved. If a protocol changes that ratio, it is a different composition and is described explicitly, not as 'diluted HMG'.
The dry vial: long in the freezer, short in the refrigerator
For a closed dry vial, follow the batch specification. The general principle for lyophilised peptides and proteins in the Bachem guide is frozen storage for long periods and a refrigerator at about +4 °C for a short working period. For long-term storage the guide describes temperatures below −15 °C, with lower temperatures preferred for longer periods.
In practice this means: if the material is set aside for a long time, choose a freezer regime the specification allows. If a dry vial will be used within a week or a month, the refrigerator is acceptable only with stability confirmed for that period. 'Up to a month' is not a universal guarantee for any batch.
In solution, HMG stability is described for the mixture as a whole, but quality control must see both components: loss of one activity is not necessarily visible from the other. The half-life of a substance in the body does not set its shelf life in a container, and the conditions for a finished registered product do not define the shelf life of a lyophilisate with a different composition.
Solution and aliquots: what the log must record
For a prepared solution, record separately the LOT, the concentration, the vehicle composition, the preparation date, the storage temperature and the number of thaw cycles. If the specification allows freezing, prepare working aliquots so that the whole stock does not have to be thawed for a single measurement. Bachem warns against long storage of peptides and proteins in solution; the suitability of a specific aliquot must be tied to verified conditions.
After a change of vehicle, concentration or container material, older stability data may no longer describe the new conditions. For a 'fresh versus stored' comparison, use a single analytical run and the same matrix. Otherwise the effect of storage is hard to separate from a change in the experiment.
What to do if the result has changed
| Situation | Useful check |
|---|---|
| One activity meets the specification, the other does not | That is a result about this batch: the activities are determined by different bioassays. Do not average them or compensate with volume. |
| Turbidity appeared after dilution | Check compatibility with the final matrix and pH. Do not treat the calculated concentrations as actually dissolved for either component. |
| An HMG result is compared with a pure FSH result | HMG also carries LH activity: the comparison is valid only in an assay that separates the contributions of both components. |
| The signal changed after the solution was stored | Compare fresh and stored aliquots in a single run and check both activities, not just one. |
Frequently asked questions
How many IU in total are in an HMG vial? The question is posed incorrectly: the vial holds 75 IU of FSH and 75 IU of LH – two different activities of two different hormones. They are not added into one number.
Can HMG be converted to milligrams? No. The mixture holds two proteins with different specific activities; the pharmacopoeial characteristic of menotropin is the pair of activities in IU from the batch COA.
How does HMG differ from HCG? HMG is two hormones, FSH and LH. HCG is a single hormone, an agonist of the LH/CG receptor, with no FSH activity. Their IU are not compared directly.
How should dry HMG and its solution be stored? A closed dry vial: the freezer for long periods, a refrigerator at about +4 °C only for a short period with confirmed stability. The solution has its own period: record the LOT, both concentrations in IU/mL, the vehicle, the date and the thaw cycles, and split the stock into aliquots.
Is the FSH:LH ratio preserved on dilution? In a simple dilution with a vehicle, yes, 1:1, because both concentrations are divided by the same factor. Any change to the ratio is a different composition.
Sources
- Lunenfeld B. Historical perspectives in gonadotrophin therapy. Human Reproduction Update. 2004;10(6):453–467. The history and composition of menotropin.
- Van Wely M, Kwan I, Burt AL, et al. Recombinant versus urinary gonadotrophin for ovarian stimulation in assisted reproductive technology cycles. Cochrane Database of Systematic Reviews. 2011;(2):CD005354. Urinary versus recombinant gonadotropins.
- European Pharmacopoeia. Menotropin monograph. Separate determination of FSH and LH activity by bioassay.
- Bachem. Handling and Storage Guidelines for Peptides. General principles for handling, dissolving and storing lyophilised peptides and proteins; not a specification for any specific batch.
HMG: pack sizes and documentation · HMG monograph · HCG: a single hormone · COA archive
A reference for working with the material. It contains no regimen for human use.
End of article
hMG (Menotropin)
for laboratory research
Packs and current prices on the product page.