In short

GLOW 70 is a blend of three peptides in one vial: GHK-Cu 50 mg, BPC-157 10 mg and TB-500 10 mg – 70 mg of lyophilized powder in total. This page brings together solution preparation, the concentrations of each component separately, and the storage rules for the dry form and for aliquots, specifically for this blend.

The key feature of a blend for laboratory practice: the dilution is shared, but the concentrations are separate. One carrier volume sets three concentrations at once in a fixed 5:1:1 ratio, and the level of one component cannot be changed without changing the others. The second feature: there are no studies of the blend itself – data exist only per component, so solution quality control is also built per component, not around the total 70 mg mass. Details are in the GLOW 70 monograph.

What a GLOW 70 vial actually contains

GHK-Cu is the copper complex of the tripeptide Gly-His-Lys; the blend holds 50 mg of it, more than two thirds of the mass. It is the copper complex that gives GHK-Cu solutions their characteristic blue tint, so the colour of a blend solution is an expected observation, not proof of purity or concentration. BPC-157 is a pentadecapeptide of 15 amino-acid residues, 10 mg per vial. TB-500 is a synthetic fragment of thymosin beta-4, also 10 mg.

When checking a specification, the COA must confirm all three components separately: the identity and content of each, not only the total powder mass. A total purity by peak area does not show whether the 50/10/10 proportion is preserved: a shift in one component's share can pass unnoticed under such a check. If the laboratory's analytical method resolves the components, the per-component values are what go into the batch log.

The 50/10/10 proportions are a commercial formula, not the result of comparative research. A practical rule follows: the blend does not replace separate component vials in experiments where concentrations must be varied independently. For such tasks the components are prepared separately; the blend suits designs where the fixed ratio is part of the design.

What to know before dissolving the lyophilisate

Record in the log the blend name, LOT, the per-component composition from the COA, the salt forms and the content data for each peptide if determined. The total 70 mg mass is the sum of three nominal values; the actual content of each component may deviate within the specification, and it is those deviations that carry into the concentration calculations.

The carrier for a blend must be compatible with the most demanding of the three components. The GHK-Cu copper complex is sensitive to medium composition: strong chelators and reducing agents in the carrier or the working matrix can change the state of the complex, so their presence is recorded and they are not introduced without need. Bachem's general guide notes that solubility depends on structure – and for a mixture of structures all the more so: carrier suitability is tested on a small trial of this exact blend.

Before opening, let a cold dry vial warm up closed to room temperature so that condensate does not reach the powder. Do not use arbitrary heating, a pH change or an organic solvent to speed up dissolution: for a blend, such an intervention can affect the three components differently, and the result will no longer be comparable with earlier series.

How to check the stock solution and the working dilution

First prepare a small trial. Add the carrier slowly down the vial wall and let the powder dissolve with gentle swirling. Record the carrier composition, the final volume, the dissolution time, the appearance and the colour. A blue tint from GHK-Cu is expected; its intensity is only a qualitative observation, not a measurement of any component's concentration.

Then reproduce the working dilution in the actual experimental medium. A blend check is complete only when the analytical method sees the components separately: a total signal can stay constant while one peptide's share changes. Separately check the sample's state at the end of the planned assay time, and compare the result of a direct dilution with the result of the full transfer chain at the same final concentrations.

If the laboratory has no per-component method, that limitation is honestly recorded in the protocol: in that case the batch identity is controlled through the supplier's COA, the appearance and the reproducibility of the total signal, but verified concentrations of individual components are not claimed. A conclusion of "solution per specification" without per-component data would be stronger than the evidence.

Mg/ml and µM: the example for GLOW 70

Mass concentration is calculated from the final volume separately for each component: c = m / V. If a 70 mg vial is dissolved to a final volume of 2 ml, the total concentration is 35 mg/ml, and per component: GHK-Cu – 25 mg/ml, BPC-157 – 5 mg/ml, TB-500 – 5 mg/ml. At 5 ml: 14 mg/ml in total, GHK-Cu – 10 mg/ml, BPC-157 – 2 mg/ml, TB-500 – 2 mg/ml. This is pack arithmetic, not a recommended concentration: the suitable volume is set by the specification and by the verified solubility of all three components.

A working dilution using c₁V₁ = c₂V₂ scales all components equally. Example: 100 µl of the stock (GHK-Cu 25 mg/ml, BPC-157 5 mg/ml, TB-500 5 mg/ml) made up to 1 ml with a compatible matrix gives GHK-Cu 2.5 mg/ml, BPC-157 0.5 mg/ml and TB-500 0.5 mg/ml. The 5:1:1 ratio is preserved at every step – both the convenience and the limitation of a blend.

No numeric molar conversion is given for the blend: a mixture has no single molar mass, and the monograph does not fix the masses of the individual components in this form. For each component separately, once the COA or specification names its confirmed molar mass M (g/mol), the conversion is the same: µM = mg/ml × 1,000,000 / M. A total "µM of the blend" is a meaningless quantity and is not used in protocols.

Dry vial: long in the freezer, short in the fridge

For the sealed dry blend, follow the batch specification. Bachem's general principle for lyophilized peptides is frozen storage for long periods and a refrigerator at about +4 °C for a short working period; for long-term storage the guide describes temperatures below −15 °C, with lower temperatures preferred for long periods. Keep the vial dry, in the dark, in a tightly closed container.

For a mixture the caution rule is stronger than for a single peptide: the dry-storage period of the blend is set by the least stable of the three components under its specification, not by the most stable one. If the component specifications diverge, the shortest applicable period is recorded in the log and followed for the whole vial.

Before every opening, a cold vial is kept closed until it reaches room temperature, so that moisture does not condense on the powder. This matters especially for a blend: the vial is usually opened many times for small weighings, and each opening is a log event with the date and the mass of the portion taken, so that the remainder and the number of openings can be reconstructed.

Solution and aliquots: what belongs in the log

For a prepared solution, record separately the LOT, the final volume, the concentrations of all three components in mg/ml, the carrier composition, the preparation date, the storage temperature and the number of thaw cycles. If the specification allows freezing the solution, prepare working aliquots so that the whole stock is not thawed for a single measurement. Bachem warns against long storage of peptides in solution; for a blend, an aliquot's fitness is tied to verified conditions for each component.

The minimum record per aliquot: batch identifier, the three component concentrations, carrier, aliquot volume, date, the operator's initials and the storage location. Do not label a blend aliquot with the total "35 mg/ml" alone: a month later such a record will not allow reconstructing how much BPC-157 or TB-500 was in the working dilution. After a change of carrier or container, the "fresh versus stored" comparison is made in a single analytical run with per-component determination, if the method allows it.

What to do if the result has changed

SituationUseful check
A different response at the same total concentrationCheck the per-component concentrations and the 5:1:1 ratio against the COA and your own analysis; the total mass may be unchanged while the composition differs.
The solution colour is noticeably different from usualCheck the carrier and matrix for chelators and reducing agents that affect the GHK-Cu copper complex; colour is a reason to check, not a verdict by itself.
Turbidity appeared after dilutionCheck compatibility with the final matrix and pH for all three components. Do not treat the calculated concentrations as actually dissolved.
The total signal is constant but the function changedA per-component analysis is needed: a total method may not see a shift in one peptide's share.

Frequently asked questions

Can the concentration of only one blend component be changed? No. Dilution scales all three components in the 5:1:1 ratio. If an experimental design needs independent concentrations, the components are prepared from separate vials.

What does the blue colour of the solution mean? It is the expected colour of the GHK-Cu copper complex. It confirms the presence of the coloured component at a qualitative level, but it does not measure the concentration of any of the three peptides.

Why is there no single µM conversion for the blend? A mixture of three different molecules has no common molar mass. µM is calculated separately for each component from its confirmed mass; a total µM for the blend has no meaning.

How long can a GLOW 70 solution be kept? The period is set by the least stable component and the verified conditions, not by the total mass. The stock is split into aliquots, repeated thaw cycles are avoided, and each aliquot's conditions are recorded.

Is a total purity of 99% in the COA enough? For a blend, no: the identity and content of each component are needed separately, otherwise the 50/10/10 proportion is unconfirmed and the per-component concentrations remain an assumption.

Sources

  1. Pickart L, Margolina A. Regenerative and Protective Actions of the GHK-Cu Peptide in the Light of the New Gene Data. International Journal of Molecular Sciences. 2018. doi:10.3390/ijms19071987. Data on the GHK-Cu component, not on the blend.
  2. Sikiric P, et al. Brain-gut Axis and Pentadecapeptide BPC 157: Theoretical and Practical Implications. Current Pharmaceutical Design. Data on the BPC-157 component.
  3. Goldstein AL, Hannappel E, Sosne G, Kleinman HK. Thymosin β4: a multi-functional regenerative peptide. Expert Opinion on Biological Therapy. Data on thymosin beta-4, of which TB-500 is a fragment.
  4. Bachem. Handling and Storage Guidelines for Peptides. General principles for handling, dissolving and storing lyophilized peptides; not a specification for a specific batch.

GLOW 70: pack sizes and documentation · The GLOW 70 monograph · COA archive

A guide for working with the material. It contains no regimen for human use.

End of article

GLOW 70

for laboratory research

Packs and current prices on the product page.