Adamax: preparation and storage
Laboratory material for research use only; not intended for human use.
Intended for research use only. Not a medicinal product.
For laboratory research only (RUO – research use only). Not a medicine, not medical advice and not instructions for human use. This guide covers only work with the material: identification, dissolution, storage and solution control.
In short
Adamax is a synthetic analogue of Semax with the same core sequence, Met-Glu-His-Phe-Pro-Gly-Pro, and protective groups at both ends of the molecule: an acetyl group at the N-terminus and an adamantane-based group at the C-terminus. In the LongEva catalogue the material is supplied as a lyophilized powder in a 10 mg vial. This page brings together solution preparation, concentration arithmetic in mg/ml and the storage rules for the dry form and for aliquots, specifically for this pack size.
The key feature of Adamax for laboratory practice is structural ambiguity on the market: close but non-identical variants of the protective groups circulate under one name. The identity of a specific batch is therefore confirmed only by its certificate of analysis (COA), not by the vial label. The second feature is the absence of published stability data for Adamax itself: solution lifetimes are not transferred from Semax; they are set from your own verified conditions or from the batch specification.
Which molecule the name Adamax describes
The core of the molecule is the heptapeptide Met-Glu-His-Phe-Pro-Gly-Pro, a stabilised ACTH(4–10) fragment that forms the basis of Semax. Adamax is set apart by two terminal modifications. N-terminal acetylation removes the free amino group that exopeptidases attack first. At the C-terminus sits an adamantane-based group – a bulky hydrocarbon cage that raises the molecule's lipophilicity. The design logic is to keep the chain intact for longer in biological media, but for Adamax itself this remains a chemical hypothesis, not a measured fact.
Three things matter when checking a specification: the full core sequence, the exact description of both terminal groups, and the salt form (counterion) in which the material is supplied. If a COA describes only a "Semax analogue" without the terminal-group structures, the batch identity is not established. The full evidence review is in the Adamax monograph; the parent molecule is described in the Semax monograph.
A practical consequence of lipophilicity: the adamantane end can change solution behaviour compared with Semax – in particular adsorption to plastic and glass, and solubility in purely aqueous carriers. A Semax dissolution recipe does not prove that the same carrier suits Adamax; compatibility is tested on a small trial of this exact batch.
What to know before dissolving the lyophilisate
Record in the log the material name, LOT, the nominal 10 mg mass, the supply form, the counterion specification and the peptide-content data if determined. The main-peak area by HPLC and the quantitative peptide content are different characteristics: a "99%" label is not enough to establish the actual substance mass for an exact concentration calculation.
Choosing a carrier requires data for this exact material form: solvent, acceptable concentration, pH and compatibility with the working medium of the experiment. Bachem's general guide explains that solubility depends on the peptide's structure and that no universal protocol exists for all peptides. If the batch specification does not name a carrier, start with a small trial in sterile water or a buffer compatible with the downstream assay, and record the result before preparing the full volume.
Before opening, let a cold dry vial warm up closed to room temperature so that condensate does not reach the powder. Do not use arbitrary heating, an abrupt pH change or an organic solvent to "rescue" a failed trial: such an intervention creates new conditions that must be documented and verified separately, not hidden in the preparation description.
How to check the stock solution and the working dilution
First prepare a small trial according to the specification. Add the carrier slowly down the vial wall and let the powder dissolve with gentle swirling; lyophilisates do not need vigorous shaking, which can produce foam that masks inhomogeneity. Record the carrier composition, the final volume, the mixing method and time, and the initial appearance. The absence of visible precipitate is a useful observation, but not a measurement of how much substance has dissolved.
Then reproduce the working dilution in the actual experimental medium, with the same carrier fraction and the same vessel material. The adamantane group makes transfer-loss checks especially relevant: compare the result of a direct dilution with the result of the full transfer chain at the same final concentration. Separately check the sample's state at the end of the planned assay time – incompatibility may appear not in the vial but only after dilution.
To assess material recovery, use a compatible analytical method, for example HPLC calibrated for this exact form. Do not judge concentration from solution clarity alone: a clear solution may contain less substance because of adsorption, while a slight opalescent tint does not by itself prove degradation.
Mg/ml and µM: the example for Adamax
Mass concentration is calculated from the final volume: c = m / V. For a 10 mg vial: dissolving to a final volume of 1 ml gives 10 mg/ml, to 2 ml gives 5 mg/ml, and to 5 ml gives 2 mg/ml. This is teaching arithmetic for the 10 mg pack, not a recommended concentration: the suitable volume is set by the batch specification and verified solubility.
For a working dilution use c₁V₁ = c₂V₂ in the same units. Example: 100 µl of a 5 mg/ml stock made up to 1 ml with a compatible matrix gives 0.5 mg/ml, that is 500 µg/ml. One further tenfold dilution gives 50 µg/ml. Record every step separately: an error in one transfer persists through all later ones.
The molar conversion for Adamax is deliberately not given as a number. The molar mass depends on the exact terminal-group variant and salt form, and the monograph does not fix a mass for this form: non-identical structures circulate under the name "Adamax". Once the COA of your batch names a confirmed molar mass M (g/mol), the conversion is: µM = mg/ml × 1,000,000 / M. The mass of Semax or of another analogue must not be used for this calculation.
Dry vial: long in the freezer, short in the fridge
For sealed dry Adamax, follow the batch specification. Bachem's general principle for lyophilized peptides is frozen storage for long periods and a refrigerator at about +4 °C for a short working period; for long-term storage the guide describes temperatures below −15 °C, with lower temperatures preferred for long periods. Keep the vial dry, in the dark, in a tightly closed container with a desiccant if the supply packaging provides one.
In practice this means: material set aside for a long time goes into the freezer under the regime the specification allows. The fridge is acceptable only for a period for which the stability of this form is confirmed. Claims of greater Adamax stability due to the terminal "caps" concern behaviour in biological media in theory and do not cancel freezer storage of the dry stock.
Every removal of a cold vial is a log event: before opening, the vial is kept closed until it reaches room temperature, so that airborne moisture does not condense on the powder. Repeated "freezer – bench – freezer" cycles without need erode confidence in stability more than one continuous period in the correct regime.
Solution and aliquots: what belongs in the log
For a prepared solution, record separately the LOT, concentration, carrier composition, preparation date, storage temperature and the number of thaw cycles. If the specification allows freezing the solution, prepare working aliquots so that the whole stock is not thawed for a single measurement. Bachem warns against long storage of peptides in solution; the fitness of a specific aliquot is tied to verified conditions, not to a calendar date.
The minimum record per aliquot: batch identifier, concentration in mg/ml, carrier, aliquot volume, date, the operator's initials and the storage location. For a more lipophilic molecule, add the tube material: switching from glass to polypropylene or back is a change of conditions after which older recovery data may no longer apply. After a change of carrier, concentration or container, the "fresh versus stored" comparison is made in a single analytical run.
What to do if the result has changed
| Situation | Useful check |
|---|---|
| A different response at the same nominal concentration | Check the LOT, the salt form in the COA, the final carrier fraction and the concentration units; repeat the comparison against a fresh reference in one run. |
| Turbidity appeared after dilution | Check compatibility with the final matrix and pH. Do not treat the calculated concentration as actually dissolved. |
| The signal falls after a series of transfers | Compare direct and serial dilution; check adsorption to the vessel material analytically. |
| The chromatographic profile and the functional result disagree | Judge each test by its purpose: HPLC answers questions about the chemical profile, a functional test about behaviour in a specific system. |
Frequently asked questions
How does Adamax differ from Semax in material handling? The core sequence is the same, but the terminal groups differ, and with them lipophilicity and potentially solubility and adsorption. The carrier and conditions for Adamax are therefore verified separately rather than copied from a Semax protocol.
Why is there no numeric µM conversion here? The molar mass depends on the exact terminal-group variant and salt form, and it is not fixed for this form. The conversion formula is given above: once a COA names a confirmed mass, µM is calculated from it, not from the mass of related analogues.
How long can an Adamax solution be kept? There are no published stability data for Adamax in solution. The period is set by the batch specification or your own verification; the stock is split into aliquots and repeated thaw cycles are avoided.
Does a clear solution mean the concentration is right? No. Clarity is only an observation. The amount of dissolved substance is confirmed by a calibrated analytical method, especially after transfers between different vessels.
Can the vial be warmed so the powder dissolves faster? Arbitrary heating is not used. A cold vial is kept closed until it reaches room temperature, and dissolution follows the specification; if a trial does not dissolve, that is a result to record, not a reason to change conditions silently.
Sources
- Dolotov OV, Karpenko EA, Inozemtseva LS, et al. Semax, an analog of ACTH(4-10) with cognitive effects, regulates BDNF and trkB expression in the rat hippocampus. Brain Research. 2006. doi:10.1016/j.brainres.2006.07.108. Data on the parent molecule, Semax, not on Adamax itself.
- Dmitrieva VG, Povarova OV, Skvortsova VI, et al. Semax and Pro-Gly-Pro activate the transcription of neurotrophins and their receptor genes after cerebral ischemia. Cellular and Molecular Neurobiology. 2010. doi:10.1007/s10571-009-9432-0.
- Bachem. Handling and Storage Guidelines for Peptides. General principles for handling, dissolving and storing lyophilized peptides; not a specification for a specific batch.
Adamax: pack sizes and documentation · The Adamax monograph · COA archive
A guide for working with the material. It contains no regimen for human use.
End of article