LONGEVA.

AOD-9604: preparation and storage

Laboratory material for research use only; not intended for human use.

AOD9604

Peptide for research

Packs

View packs and prices

Intended for research use only. Not a medicinal product.

For laboratory research only (RUO – research use only). Not a medicine, not medical advice and not instructions for human use. This guide covers only work with the material: identification, dissolution, storage and solution control.

In short

AOD-9604 is a synthetic analogue of the C-terminal fragment of human growth hormone with the sequence Tyr-Leu-Arg-Ile-Val-Gln-Cys-Arg-Ser-Val-Glu-Gly-Ser-Cys-Gly-Phe and an intramolecular disulfide bridge between the two cysteines. In the LongEva catalogue the material is supplied as a lyophilized powder in a 5 mg vial. This page brings together solution preparation, concentration arithmetic in mg/ml and the storage rules for the dry form and for aliquots, specifically for this pack size.

Two features of the molecule define laboratory practice. The first is the added N-terminal tyrosine: it is what distinguishes AOD-9604 from the unmodified fragment 176–191, and its presence is what the COA must confirm. The second is the disulfide bridge: media with reducing agents and harsh conditions can alter the molecule, so the carrier and matrix composition for this peptide is recorded with particular care. Details are in the AOD-9604 monograph.

Which molecule the name AOD-9604 describes

AOD-9604 was created at Australia's Metabolic Pharmaceuticals in the 1990s as an analogue of the growth-hormone fragment 176–191: a tyrosine was added at the N-terminus of the fragment sequence, and the literature writes the construct as Tyr-hGH[177-191]. The two cysteine residues in the chain are joined by a disulfide bridge that closes part of the molecule into a loop. That loop is part of the chemical identity: material with a broken or incorrectly closed bridge is no longer the same substance for analytical purposes.

Three features matter when checking a specification: the full sequence with the N-terminal tyrosine, the presence of the Cys–Cys disulfide bridge, and the salt form. If a COA describes simply "fragment 176–191" without the tyrosine, you may be looking at the unmodified fragment – a close relative, but a different material with its own catalogue card. The same vial mass does not make the two substances interchangeable in an experiment.

The evidence context is also part of the material's identity: in animal models the fragment accelerated lipolysis, but the pivotal phase IIb study in humans (2007) did not meet its primary endpoint, and development as a medicine was stopped. For solution work a sober rule follows: no laboratory procedure "improves" the substance, and the concentrations in protocols describe only experimental conditions, not an expected effect in humans.

What to know before dissolving the lyophilisate

Record in the log the material name, LOT, the nominal 5 mg mass, the sequence from the COA, the disulfide-bridge state per the specification, the salt form and the peptide-content data if determined. The main-peak area by HPLC and the quantitative content are different characteristics: for the analytics of a disulfide-containing peptide it also matters whether the method distinguishes forms with an intact bridge from forms with a damaged one.

Choosing a carrier requires data for this exact form: solvent, pH, acceptable concentration and compatibility with the working medium. A separate point for AOD-9604 is reducing agents: media containing strong reducing agents can break disulfide bonds, so their presence in the carrier or matrix is either excluded or consciously recorded as an experimental condition. Bachem's general guide explains that solubility depends on the peptide's structure and that no universal protocol exists; carrier suitability is tested on a small trial.

Before opening, let a cold dry vial warm up closed to room temperature so that condensate does not reach the powder. Do not use arbitrary heating or a pH change to speed up dissolution: such an intervention creates new conditions that must be documented and verified, not hidden in the preparation description.

How to check the stock solution and the working dilution

First prepare a small trial according to the specification. Add the carrier slowly down the vial wall and let the powder dissolve with gentle swirling; vigorous shaking is not needed. Record the carrier composition, the final volume, the dissolution time and the initial appearance. The absence of visible precipitate is a useful observation, but not a measurement of how much substance has dissolved.

Then reproduce the working dilution in the actual experimental medium, and separately check the sample's state at the end of the planned assay time. For a disulfide-containing peptide, the "fresh versus stored" comparison should include a method able to show a change in the chromatographic profile, not only a total signal: partial damage to the bridge may not change the total mass of dissolved substance, but can change its behaviour in the test.

If the work involves serial dilutions or several transfers, include the whole chain in the reproducibility check: compare a direct dilution with the serial path at the same final concentration. A discrepancy is a reason to check vessels, matrix and incubation conditions, not to adjust the final figure.

Mg/ml and µM: the example for AOD-9604

Mass concentration is calculated from the final volume: c = m / V. For a 5 mg vial: dissolving to a final volume of 1 ml gives 5 mg/ml, to 2 ml gives 2.5 mg/ml, and to 5 ml gives 1 mg/ml. This is arithmetic for the 5 mg pack, not a recommended concentration: the suitable volume is set by the batch specification and verified solubility.

For a working dilution use c₁V₁ = c₂V₂ in the same units. Example: 100 µl of a 5 mg/ml stock made up to 1 ml with a compatible matrix gives 0.5 mg/ml, that is 500 µg/ml. One further tenfold dilution gives 50 µg/ml. Record every step separately: an error in one transfer persists through all later ones.

The molar conversion is deliberately not given as a number: the monograph does not fix a molar mass for this form, and the mass depends on the confirmed sequence and the salt form of the specific batch. Once the COA names a confirmed molar mass M (g/mol), the conversion is: µM = mg/ml × 1,000,000 / M. The mass of the unmodified fragment 176–191 must not be used for AOD-9604: the added tyrosine changes both the mass and the substance itself.

Dry vial: long in the freezer, short in the fridge

For sealed dry AOD-9604, follow the batch specification. Bachem's general principle for lyophilized peptides is frozen storage for long periods and a refrigerator at about +4 °C for a short working period; for long-term storage the guide describes temperatures below −15 °C, with lower temperatures preferred for long periods. Keep the vial dry, in the dark, in a tightly closed container.

In practice this means: material set aside for a long time goes into the freezer under the regime the specification allows. The fridge is acceptable only for a period with confirmed stability for this form. The disulfide bridge is more stable in a dry lyophilisate than in solution, but that is no reason to keep the vial warm and humid: moisture at openings is the main controllable risk for the dry stock.

Before every opening, a cold vial is kept closed until it reaches room temperature, so that condensate does not settle on the powder. The number and dates of openings are recorded in the log: for material taken in small portions from a single 5 mg vial, the opening history is part of the batch history.

Solution and aliquots: what belongs in the log

For a prepared solution, record separately the LOT, concentration, carrier composition, preparation date, storage temperature and the number of thaw cycles. If the specification allows freezing the solution, prepare working aliquots so that the whole stock is not thawed for a single measurement. Bachem warns against long storage of peptides in solution; the fitness of a specific aliquot is tied to verified conditions.

The minimum record per aliquot: batch identifier, concentration in mg/ml, carrier, aliquot volume, date, the operator's initials and the storage location. For AOD-9604, add a line on the composition of the final experimental matrix, in particular the absence or presence of reducing agents: without that record, a later change in profile cannot be distinguished from a storage effect. After a change of carrier, concentration or container, the "fresh versus stored" comparison is made in a single analytical run.

What to do if the result has changed

SituationUseful check
A different response at the same nominal concentrationCheck the LOT, the sequence in the COA (presence of the N-terminal tyrosine), the salt form and the concentration units; repeat the comparison against a fresh reference in one run.
The chromatographic profile changed after storageCheck the storage conditions and the matrix composition, in particular reducing agents able to affect the disulfide bridge.
Turbidity appeared after dilutionCheck compatibility with the final matrix and pH. Do not treat the calculated concentration as actually dissolved.
The total dissolved mass is the same but the function differsAssess the profile with a method that distinguishes the molecule's forms; a total method may not see a change in the bridge.

Frequently asked questions

How does AOD-9604 differ from fragment 176–191 in handling? By the added N-terminal tyrosine. It is a different molecule with a different mass, so COAs, standards and calculations are kept separately for them, and the vials are not interchangeable.

Why is the matrix composition so important for this peptide? The molecule contains a Cys–Cys disulfide bridge. Strong reducing agents in the carrier or matrix can break it, so their presence is either excluded or consciously recorded as an experimental condition.

Why is there no numeric µM conversion here? The molar mass of this form is not fixed in the monograph, and it depends on the confirmed sequence and the batch's salt form. The conversion formula is given above; the mass of the unmodified fragment must not be substituted.

How long can an AOD-9604 solution be kept? There is no universal period: it is set by the batch specification or by your own stability verification with a method that sees the molecule's profile. The stock is split into aliquots and repeated thaw cycles are avoided.

Does a clear solution mean the bridge is intact? No. Clarity is only an appearance observation. The molecule's state is shown by an analytical method able to distinguish its forms.

Sources

  1. Heffernan MA, Thorburn AW, Fam B, et al. The effects of human GH and its lipolytic fragment (AOD9604) on lipid metabolism following chronic treatment in obese mice and beta(3)-AR knock-out mice. Endocrinology. Animal-model data on the fragment and AOD-9604.
  2. Ng FM, Sun J, Sharma L, et al. Metabolic studies of a synthetic lipolytic domain (AOD9604) of human growth hormone. Journal of Molecular Endocrinology. Structure and metabolic studies of the synthetic fragment.
  3. Bachem. Handling and Storage Guidelines for Peptides. General principles for handling, dissolving and storing lyophilized peptides; not a specification for a specific batch.

AOD-9604: pack sizes and documentation · The AOD-9604 monograph · COA archive

A guide for working with the material. It contains no regimen for human use.

End of article

AOD9604

for laboratory research

Packs and current prices on the product page.

View packs and prices